Jonik, Sarahrose; Rothka, Andrew J.; Cherin, Neyha. Therapeutic Advances in Chronic Disease 2025; 16
Kurz erklärt
This review has compiled the existing research on microcurrent therapy, and the studies analysed predominantly report benefits. Microcurrent therapy uses currents so weak that they cannot be felt. Ischaemic wounds – that is, wounds with poor blood supply – healed twice as fast with this treatment as with a placebo. In cases of acute knee injuries, patients experienced less pain and improved mobility. Improvements were also reported in fibromyalgia, pain following spinal cord injury, and in cases of anxiety and depression. Side effects were rare and occurred in fewer than 1 per cent of patients receiving ear-clip stimulation.
Übertragbarkeit auf den HD2000+
Stufe B Vergleichbare Parameter
The parameters mentioned in the study fall within the operating range of the HD2000+
Für Fachleute
This narrative review is based on 57 sources from PubMed, Web of Science, the Cochrane Library and Scopus. It examines clinical endpoints such as pain, healing rates and quality of life in the fields of rehabilitation, chronic pain, wound healing, psychiatry and neurocognition, as well as in supportive cancer care. In wound healing, ischaemic wounds healed twice as fast with microcurrent treatment as with sham treatment. Currents of 50–100 µA reduced the time taken for wound closure in burns by 36 per cent, and currents above 300 µA accelerated the healing of grade 2 and 3 pressure ulcers. A meta-analysis of randomised trials found microcurrent to be superior to standard wound care, with additional pain relief. A double-blind RCT in acute knee injuries showed reduced pain and improved function, with a significant benefit from week 3 onwards (p < 0.01). Further positive reports relate to knee osteoarthritis, temporomandibular joint disorders, the post-operative period following knee replacement surgery, fibromyalgia, pain following spinal cord injury, and anxiety or depression in conjunction with cranial electrostimulation (side effects in < 1%). The mechanisms under discussion include membrane potential, calcium influx, ATP synthesis and angiogenesis.
Einschränkungen
This is a narrative overview.
Bewertungsgrundlage: Volltext geprüft · zuletzt geprüft am 19 Nov 2026. Diese Datenbank informiert über veröffentlichte Forschung. Sie ersetzt keine ärztliche Beratung und ist kein Wirksamkeitsversprechen. Die Einordnung stammt von der LuXXaMed GmbH als Hersteller des HD2000+.